Econex R32 Inverter

Econex R32 Inverter

Australia | Ducted Split Systems | Econex R32 Inverter

TZ_ECONEX_LOGO_2.jpg

High Performance Low GWP systems
 

 
 

Temperzone Econex Ducted Split systems are leading the way in providing low GWP commercial R32 air conditioning solutions.

Combining the latest inverter technology and R32 refrigerant, our Econex range provides the best of both worlds - increased efficiency and performance - with reduced global warming potential.

Econex R32 Inverter Ducted Split



 


Available in

Reverse Cycle (Heating and Cooling)

Capacity Range Nominal kW (Cooling)

14.8 (8.6~18.5), 19.5 (9.4~25.3),
23.3 (13.3~29.5), 35.1 (15.0~43.0)

Refrigerant

R32

High Performance

These low GWP Ducted Split systems offer increased performance with extra wide capacity ranges for complete specification flexibility.

R32 Refrigerant

 

With a smaller refrigerant charge and a GWP of 677, R32 refrigerant represents a 75-80% reduction in overall GWP per kW of cooling or heating when compared to R410a systems (GWP 2088).
As higher GWP refrigerants face increasing cost due to emissions tax levies the specification of R32 systems will represent a significant reduction in the future costs associated with maintaining these systems.

Boosted Capacity

 

Extreme weather operation For versatile specification, all R32 inverter ducted split systems offer a very wide heating and cooling capacity range enabling reliable comfort at times of peak load and increased energy savings under low load conditions.

Inverter Compressors

 

Econex Ducted Split Systems utilise inverter compressor technology providing superior part load performance and close comfort control. Our Econex inverter units feature a stepless capacity control that enables the achievement of precise comfort settings. In contrast, non-variable capacity units attempt to maintain temperature by repeatedly switching power on and off, thereby generating greater temperature fluctuations and higher energy use.

Extreme Weather operation

 

Designed for the harshest conditions these R32 ducted units are designed to operate in ambient temperatures from -15°C to 52°C to ensure you're always comfortable, whatever the weather

Intelligent De-ice

 

New intelligent de-ice enables improved performance in colder conditions. Optimised coil circuitry and new unit controller logic has resulted in faster and more effective de-ice.

EC Fan Technology

 

Our high-efficiency EC fan motors are 20% more energy efficient than AC motor alternatives and enable quiet operation with slow ramp-up and no sudden noise changes. Achieve precise comfort with custom select fan speeds or continuously variable fan speed control.

Electronic Expansion Valves

 

EEVs enable improved efficiency and reduced operating costs at part-load conditions. They also facilitate maximised energy savings during the shoulder seasons – periods in which air conditioning systems often run at part-load.

Climate Touch

 

Temperzone's new Climate Touch gives you complete control over your comfort. Contemporary and convenient, it is designed to seamlessly fit into modern residential and commercial environments while delivering comprehensive yet simple control of your comfort. For convenience the thermostat can be easily wired to either the Indoor or Outdoor Unit.

BMS Connectivity

 

Econex Ducted Split can connect into a BMS for control and operation.

  • Through the outdoor unit for multi-unit control capability.
  • Through the indoor unit for centralised 0-10Vdc fan speed control.
  • Up to 99 units can be connected on a common RS458 bus in daisy chain design.
  • Daisy chain wiring saves on amount of wiring and required labour time.
  • BMS communication cable (2-wire shielded) with maximum cable length of 1000m

 

Easy Wiring

 

Wiring and pipe access is made easy and convenient with a new removable corner access panel for electrical and piping access. Easy installer electrical access with connections more easily accessed through the corner panel. Outdoor units are fully wired and the main power supply along with communication connections can be easily wired directly within the panel.

Zone Control*

 

Offering a simple and elegant solution to the challenge of multi-zone temperature requirements, Temperzone ducted air conditioning systems enable the comfort levels of designated spaces to be individually set and maintained via one concealed common unit. Using the optional zone relay board which is installed in the indoor unit, dampers and sensors are easily wired into the system where they can communicate with the temperzone controller and outdoor unit for precise zone temperature and airflow control.
* Important note: when designing a zoned system, the smallest zone must meet the minimum space requirements for R32 refrigerant.


R32 REFRIGERANT

R32 refrigerant has a significantly lower GWP than R410a


INVERTER COMPRESSOR

Inverter compressor for superior part load performance.


EC FAN

Variable fan speed control
0-10VDC input


ELECTRONIC VALVES

Electronic expansion valves for greater control and efficiency

Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase Specifications
Technical Data
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase Specifications
Technical Data
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32 Specifications
Technical Data
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32 Specifications
Technical Data
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32 Specifications
Technical Data
Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase I&M
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase I&M
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32 I&M
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32 I&M
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32 I&M
Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase DXF File Indoor Unit
DXF File Outdoor Unit
RFA Files
RFA File Outdoor Unit
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase DXF File Indoor Unit
DXF File Outdoor Unit
RFA Files Indoor Unit
RFA File Outdoor Unit
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32 DXF File Indoor Unit
DXF File Outdoor Unit
RFA Files Indoor Unit
RFA File Outdoor Unit
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32 DXF File Indoor Unit
DXF File Outdoor Unit
RFA Files Indoor Unit
RFA File Outdoor Unit
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32 DXF File Indoor Unit
DXF File Outdoor Unit
RFA Files Indoor Unit
RFA File Outdoor Unit
Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32
Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32
Model Information
OSA 171RLSFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Single Phase
OSA 171RLTFH/ISD 171LYX, 14.8kW Econex Ducted Split System, R32, Three Phase
OSA 211RLTFH/ISD 211LYX, 19.5kW Econex Ducted Split System, R32
OSA 251RLTFH/ISD 251LYX, 23.3kW Econex Ducted Split System, R32
OSA 351RLTFV/ISD 351LYX, 35.1kW Econex Ducted Split System, R32